CSI Ningdong N160/N170 Series Marine Diesel Generator Set (200 – 500kW)

Standard and Optional Parts

Absorber: standard

Cylinder freshwater heater: standard for self-start engine

Pregreasing pump: standard for self-start engine

Governor: electronic governor (standard)

Silencer: optional

Lifting device: standard

Parameters Table

Item Unit Technical Parameters
Engine Type Four-stroke, water-cooled, in-line, turbocharged and intercooled, direct injection
Cylinder Bore × Stroke mm 160/170 × 200
No. Cylinder 6 / 8
Revolution rpm 1000 – 1500
Compression Ratio 14.5 : 1
SFOC g/kW·h 196+3%
SLOC g/kW·h ≤0.7
Cooling System Closed circulating water cooling
Alignment Method Flexible coupling
Starting Mode Compressed air motor
Minimum Height for Lifting Piston mm 1260 (above crankshaft centerline)
NOX Emission Standard IMO Tier II, GB 15097-2016 1st
Generator Rated Power kW 200 – 500
Power Factor  0.8(lagging)
 

Voltage

Steady state voltage regulating rate % <±2.5
Transient voltage regulating rate % -15~+20
Stabilization time s <1.5
Voltage fluctuation rate % ≤±1
 

Frequency

Steady state frequency (rev.) regulating rate % <5(parallel)
Transient frequency (rev.) regulating rate % ≤±10
Stabilization time s <5
Frequency fluctuation rate % ≤±0.5

Model Portfolio Table

Generator Model Rated Power

(kW)

Rated

Speed

(rpm)

Engine Alternator model  

Dimensions

(mm)

Net Weight

(Kg)

Engine model Rated Power(kW)
CCFJ200J(Z)-W01 200 1000 N6160ZLCD2 235.3 TFXW-355-6-H 3660×1280×1805 5270
CCFJ200J(Z)-W02 1FC6 355-6SA42 3840×1280×1805 5420
CCFJ200J(Z)-W03 1FC5 356-6TA42
CCFJ200J(Z)-W01A N6170ZLCD2 250 TFXW-355-6-H 3640×1412×1816 5480
CCFJ200J(Z)-W02A 1FC6 355-6SA42 3859×1412×1816 5650
CCFJ250J(Z)-W01 250 1000 N6160ZLCD6 294 TFXW-355-6-H 3660×1280×1805 5380
CCFJ250J(Z)-W02 1FC6 356-6SA42 3840×1280×1805 5500
CCFJ250J(Z)-W03 1FC5 356-6TA42
CCFJ250J(Z)-W01A N6170ZLCD4 330 TFXW-355-6-H 3640×1412×1816 5590
CCFJ250J(Z)-W02A 1FC6 356-6SA42 3859×1412×1816 5730
CCFJ280J(Z)-W01 280 1000 N6160ZLCD8 331 TFXW-355-6-H 3760×1280×1805 5500
CCFJ280J(Z)-W02 1FC6 404-6SA42 3940×1280×1805 5690
CCFJ280J(Z)-W03 1FC5 404-6TA42
CCFJ280J(Z)-W01A N6170ZLCD4 330 TFXW-355-6-H 3740×1412×1816 5780
CCFJ280J(Z)-W02A 1FC6 404-6SA42 3985×1412×1806 5970
CCFJ300J(Z)-W01 300 1000 N8160ZLCD6 353 TFXW-355-6-H 4285×1280×1843 6320
CCFJ300J(Z)-W02 1FC6 405-6SA42 4520×1280×1842 6520
CCFJ300J(Z)-W03 1FC5 406-6TA42
CCFJ300J(Z)-W06 1FC2 451-6SB42
CCFJ300J(Z)-W01A N6170ZLCD4 330 TFXW-355-6-H 3740×1412×1816 5780
CCFJ300J(Z)-W02A 1FC6 405-6SA42 3985×1412×1816 6070
CCFJ320J(Z)-W03 320 1000 N8160ZLCD 400 1FC5 406-6TA42
CCFJ320J(Z)-W06 1FC2 451-6SB42
CCFJ350J(Z)-W01 350 1000 N8160ZLCD 400 TFXW-400-6-H 4450×1280×1938 6920
CCFJ350J(Z)-W02 1FC6 406-6SA42 4520×1280×1843 6620
CCFJ350J(Z)-W03 1FC5 406-6TA42
CCFJ350J(Z)-W08A 1500 N6170ZLCD13 400 TFXW-355-4-H 3640×1591×1816 5630
CCFJ350J(Z)-W09A 1FC6 403-4SA42 3985×1591×1816 5790
CCFJ350J(Z)-W01A 1000 N8170ZLCD11 400 TFXW-400-6-H 4376×1519×1979 7160
CCFJ350J(Z)-W02A 1FC6 406-6SA42 4456×1519×1979 7010
CCFJ380J(Z)-W06 380 1000 N8160ZLCD14 441 1FC2 452-6SB42
CCFJ400J(Z)-W01 400 1000 N8160ZLCD14 464 TFXW-400-6-H 4450×1280×1938 6920
CCFJ400J(Z)-W02 1FC6 408-6SA42 4590×1280×1843 6770
CCFJ400J(Z)-W06 1FC2 452-6SB42 4475×1280×1938 7120
CCFJ400J(Z)-W08A 1500 N6170ZLCD14 450 TFXW-355-4-H 3640×1591×1816 5780
CCFJ400J(Z)-W09A 1FC6 405-4SA42 3985×1591×1816 5830
CCFJ400J(Z)-W01A 1000 N8170ZLCD1 441 TFXW-400-6-H 4376×1591×1979 7160
CCFJ400J(Z)-W02A 1FC6 408-6SA42 4526×1519×1979 7160
CCFJ400J(Z)-W06A 1FC2 452-6SB42 4376×1519×1979 7460
CCFJ500J(Z)-W08A 500 1500 N8170ZLCD4 600 TFXW-355-4-H 4204×1526×1979 6980
CCFJ500J(Z)-W09A 1FC6 453-4SA42 4376×1526×1979 8090
CCFJ500J(Z)-W05A 1FC2 451-4SB42 4369×1526×1979 7360

Outline

CSI Ningdong N160N170 Series Marine Diesel Generator Set (200 - 500kW)

Notes:

  1. “CCFJ***J-W**” means conventional generator set, and “CCFJ***Z-W” means self-starting type generator set.
  2. This model portfolio is mainly about 50Hz, 400V, and 60Hz products with corresponding powers that can be also produced according to customer requirements, please contact relevant personnel for specific specifications and technical parameters.
  3. For generator set model selection, please make communicate with relevant personnel.
  4. The delivery scope for each model engine shall be performed as per the corresponding technical files.
  5. Dimensions and weight are for reference only.
RELATE PRODUCTS